HYDRAULIC AND ELECTRIC ELEVATORS FOR USE IN GOODSLIFTS AND VEHICLES LIFTS
THERE ARE PROVIDED 4 MAIN TYPES OF INSTALLATION:
OLC Hydraulic Lifting Direct Central Piston.
OL2L Hydraulic Lifting Two Lateral Pistons.
EMA Electric Lifting Machinery at the top
EMB Electric Lifting Machinery at the bottom.
OLC Hydraulic Lifting Direct Central Piston.
OL2L Hydraulic Lifting Two Lateral Pistons.
EMA Electric Lifting Machinery at the top
EMB Electric Lifting Machinery at the bottom.
Depending on the load and the necessary size of the cabin(1), it is possible to identify for each type of installation, the necessary dimensions for the hoistway, according to the following table:
TIPO ASCENSORE ELEVATOR TYPE TIPO ASCENSOR | LV mm | PV mm | T mm | F mm | LOCALE MACCHINARIO MACHINE ROOM SALA DE MAQUINAS |
||
---|---|---|---|---|---|---|---|
W | D | H | |||||
OLC | LC+500 | PC+500 | HC+1300 | 1500 | 2000 | 2000 | 2000 |
OL2L | LC+1000 | PC+500 | HC+1500 | 1500 | 2000 | 2000 | 2000 |
EMA | LC+750 | PC+500 | HC+1700 | 1700 | 3200 | 4900 | 2400 |
EMB | LC+750 | PC+500 | HC+2500 | 1700 | 2500 | 2500 | 2000 |
LC= Car width
AP= Door width
T= Overhead – Distance between the highest floor, served by car, and the ceiling of the hoistway
PC= Car depth
HP= Door height
C= Travel – Distance between the lowest floor, served by car, and the highest floor.
HC= Car height
CI= CTravel between floors
F= Pit – Useful space below the level of the lowest floor, served by car
(1)Mandatory standards for elevator installations require that the surface and the capacity of the car are interdependent on the basis of specific tables: